multipeak fitting tool from igor pro Search Results


90
wavemetrics inc multipeak fitting package igor pro
Multipeak Fitting Package Igor Pro, supplied by wavemetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multipeak+fitting+tool+from+igor+pro/10__1039_slash_d0ra01295e-85-16-21?v=wavemetrics+inc
Average 90 stars, based on 1 article reviews
multipeak fitting package igor pro - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
wavemetrics inc multipeak fitting package
Multipeak Fitting Package, supplied by wavemetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multipeak+fitting+tool+from+igor+pro/pmc07984230-119-17-22?v=wavemetrics+inc
Average 90 stars, based on 1 article reviews
multipeak fitting package - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
wavemetrics inc sum of two gaussian functions
Thickness of the axon shafts of cone (CBC2–CBC8) and rod (RBC) bipolar cells at five different positions (with approximately equidistant spacing) from the cell body to the axon terminal (position 1 closest to the cell body, position 5 closest to the axon terminal). For each position, we generated a transverse intensity profile along a straight line (oriented perpendicularly to the local longitudinal axis of the axon) from the deconvolved image stack used for morphological reconstruction. For a given location, the intensity profile was generated from the focal plane (slice), where the width was at its maximum. For each intensity profile, the width was taken as the full width at half‐maximum (FWHM), estimated from a <t>Gaussian</t> fit. Notice that the FWHM values for rod and cone bipolar cells completely overlap
Sum Of Two Gaussian Functions, supplied by wavemetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multipeak+fitting+tool+from+igor+pro/pmc09310816-139-10-18?v=wavemetrics+inc
Average 90 stars, based on 1 article reviews
sum of two gaussian functions - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

90
wavemetrics inc lorentzian peak fitting multipeak fit 2
Thickness of the axon shafts of cone (CBC2–CBC8) and rod (RBC) bipolar cells at five different positions (with approximately equidistant spacing) from the cell body to the axon terminal (position 1 closest to the cell body, position 5 closest to the axon terminal). For each position, we generated a transverse intensity profile along a straight line (oriented perpendicularly to the local longitudinal axis of the axon) from the deconvolved image stack used for morphological reconstruction. For a given location, the intensity profile was generated from the focal plane (slice), where the width was at its maximum. For each intensity profile, the width was taken as the full width at half‐maximum (FWHM), estimated from a <t>Gaussian</t> fit. Notice that the FWHM values for rod and cone bipolar cells completely overlap
Lorentzian Peak Fitting Multipeak Fit 2, supplied by wavemetrics inc, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/product/multipeak+fitting+tool+from+igor+pro/10__1063_slash_1__4929880-37-9-18?v=wavemetrics+inc
Average 90 stars, based on 1 article reviews
lorentzian peak fitting multipeak fit 2 - by Bioz Stars, 2026-08
90/100 stars
  Buy from Supplier

Image Search Results


Thickness of the axon shafts of cone (CBC2–CBC8) and rod (RBC) bipolar cells at five different positions (with approximately equidistant spacing) from the cell body to the axon terminal (position 1 closest to the cell body, position 5 closest to the axon terminal). For each position, we generated a transverse intensity profile along a straight line (oriented perpendicularly to the local longitudinal axis of the axon) from the deconvolved image stack used for morphological reconstruction. For a given location, the intensity profile was generated from the focal plane (slice), where the width was at its maximum. For each intensity profile, the width was taken as the full width at half‐maximum (FWHM), estimated from a Gaussian fit. Notice that the FWHM values for rod and cone bipolar cells completely overlap

Journal: The Journal of Comparative Neurology

Article Title: Digital reconstruction and quantitative morphometric analysis of bipolar cells in live rat retinal slices

doi: 10.1002/cne.25308

Figure Lengend Snippet: Thickness of the axon shafts of cone (CBC2–CBC8) and rod (RBC) bipolar cells at five different positions (with approximately equidistant spacing) from the cell body to the axon terminal (position 1 closest to the cell body, position 5 closest to the axon terminal). For each position, we generated a transverse intensity profile along a straight line (oriented perpendicularly to the local longitudinal axis of the axon) from the deconvolved image stack used for morphological reconstruction. For a given location, the intensity profile was generated from the focal plane (slice), where the width was at its maximum. For each intensity profile, the width was taken as the full width at half‐maximum (FWHM), estimated from a Gaussian fit. Notice that the FWHM values for rod and cone bipolar cells completely overlap

Article Snippet: Each intensity profile was fitted with the sum of two Gaussian functions (MultiPeak Fit package in IGOR Pro; WaveMetrics, Lake Oswego, OR, USA; RRID: SCR_000325) and the axon diameter was estimated as the distance between the locations of the two peaks.

Techniques: Generated